Finding the flaw without cutting anything open.
Non-destructive testing detects and evaluates discontinuities in a material without harming the material being tested. What is found is then classified as a flaw or a defect against the applicable code, which is the part that decides whether your asset runs on.
Seven ways to look inside something you are not allowed to open.
Plain English first, the acronym second. Each method has a reason it is the right one for a given material, geometry and defect type, and picking the wrong one is how a flaw gets missed.
Liquid penetrant testing (PT)
Magnetic particle testing (MT)
Ultrasonic testing (UT)
Eddy current testing (ET)
Radiography testing (RT)
Visual testing (VT)
Positive material identification (PMI)
Where the geometry is hard, or the unit cannot come off line.
This is the half of the discipline that separates an inspection contractor from a technician with a probe, and it is what makes on-stream inspection possible at all.
Shell thickness, floor plates and tank calibration.
The purpose of a tank NDT is to find deterioration or flaws in the structure that could cause a leak or a failure. Testing covers shell thickness for corrosion and excessive wear, and identifies cracks, laminations, voids, bulges and indentations, along with blocked drains, blocked vents and defective ladders and stairways.
Methods include visual inspection, ultrasonic thickness measurement, surface defect detection by penetrant, eddy current or magnetic particle, and volumetric defect detection by radiography or ultrasonics. 3D laser scanning and floor scans are also run to produce visual maps of floor-plate and shell condition.
Tanks of any size, shape or design are inspected and calibrated, including tanks holding crude oil, petroleum products and LPG, and ammonia storage tanks, which need a specific competence in ammonia tank design and operation.
Independent inspectors, with the certificate.
Independent inspectors give condition reports on storage tanks, pipework, pressure vessels, oil wells, valves and pumps, and can issue certificates of compliance alongside the report where the structure falls within the specified tolerances.
The scope covers NDT, storage tank, pipework, plant, pump and valve, weld and paint, assembly, and access and safety inspections, for oil and gas, marine, petrochemical, energy and food and beverage storage.
The general manager for commercial and projects is an ASME/NBBI authorised inspector, a CSWIP 3.1 welding inspector and an ISO 9001 lead auditor, with over 30 years in inspection and quality assurance.
Send the drawing and the code.
Share the asset, the material, the geometry and the standard you are inspecting to, and the reply says which method fits and whether it can be done on stream.
Finding it is half the job. The other half is putting it right without a second mobilisation.